I/O Timing Diagrams

This page details digital I/O timing specifications for the OV20i, including trigger signal timing, output latency, and recommended pulse widths.


Digital Input Timing

Trigger Input Timing (Pin 16)

ParameterSpec
Input Activation TypeNPN (Pull to GND)
Minimum Pulse Width10 ms
Input Debounce~5 ms
Max Input Frequency~20 Hz
Signal TypeDry contact or open collector

Trigger fires once per pulse

Ideal for sensors with clean output transitions


Digital Output Timing

Result Output Timing (Pins 10 & 11)

EventTiming
Output Activation Delay~10–15 ms after inference
Output Active DurationConfigurable (default 100 ms)
Max Current100 mA
Output Logic TypeNPN open collector (pulls to GND)
note

External pull-up to 24 VDC is required for most PLCs.


Typical Timing Sequence (Digital Trigger)

CopyEdit
Trigger Pulse
___
| |____________________
|
|<-- 10 ms -->|

Inference Timing (AI Process)
_______________________
/
Result Output __/

|<-- ~10–15 ms after trigger -->|


  • Trigger via dry contact, NPN sensor, or PLC sinking output
  • Set minimum pulse width: 10–20 ms
  • Configure output duration via UI or PLC tag if required

image.png


Best Practices

image.png

  • Use shielded cables to minimize noise
  • Confirm rising/falling edge behavior matches PLC expectations
  • Check output with a test light or multimeter during setup
  • Avoid signal bounce by using sensors with built-in debounce